Answers Database


PPR 5.2.x: XC5200 design with Readback gives ERROR 9905: NET "$I417/CLK" has no source


Record #2094

Product Family: Software

Product Line: XACT FPGA

Product Part: ppr

Product Version: 5.2.1

Problem Title:
PPR 5.2.x: XC5200 design with Readback gives ERROR 9905: NET "$I417/CLK" has no source


Problem Description:
Urgency: Standard

General Description:

*** PPR: ERROR 9905:
     Net "$I417/CLK" has no source.
     The router cannot continue until this functional error
     is corrected.


Solution 1:

This error has been observed in an XC5202 design using the READBACK symbol. By default , when no s ignal is connected to the CLK input, the internal CCLK is to be used.

If this error occurs, replace the READBACK symbol with the
RDBK symbol - which is comprised of TRIG, DATA, and RIP
pins - and no CLK input.




End of Record #2094 - Last Modified: 10/27/97 15:53