Answers Database


Foundation: BTRIEVE error 88 - incompatible mode error


Record #2152

Product Family: Software

Product Line: Aldec

Product Part: Foundation Project Manager

Problem Title:
Foundation: BTRIEVE error 88 - incompatible mode error


Problem Description:
Urgency: Standard

General Description:
While trying to open a file, if the following message is
reported:

Btrieve 88 : The application encountered an incompatible mode
           error
Lm_acs : Btrieve cannot open file - '<filename>', err: 88
3839 LM internal error
Library Error = 3839


Solution 1:

The project manager may be trying to access a file that
is currently being used by another application. Close any
programs that may be accessing the file.



Solution 2:

This error can occur when <filename> is on a network,
and the file is locked.

If the file is being accessed by another user, you will not
be able to open the file until it has been released.

The file may also be locked if the application or system
crashed the last time this file was open (e.g. the PC
crashed while you were editing a schematic). Procedures
for unlocking the file will vary depending on the type of
network. Consult your systems administrator.




End of Record #2152 - Last Modified: 05/02/97 10:31

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!