Answers Database


OrCAD Capture: Design rule check gives "no matching pin" error for OFD16 component


Record #2177

Product Family: Software

Product Line: OrCAD

Product Part: capture

Problem Title:
OrCAD Capture: Design rule check gives "no matching pin" error for OFD16 component


Problem Description:
Priority: Urgency

Problem Description:
If you are using an OFD16 in an Orcad Capture design, you may get the following warning from the des ign rule checker:

  [DRC0012] Pin has no matching port in schematic below U...
  and
  [DRC0013]: Port has no matching pin in part instance above...

  This warning message may be due to a problem with the library
symbol. Descend into the OFD16 component and check to see if
the output and input bus names have an index [15.0] instead of
[15..0] as they should be. (This was a problem in the original
Capture libraries.)
Orcad has been notified of this error.


Solution 1:

Call Orcad technical suppport for an updated library or descend into the OFD16 and change the bus in dex to [15..0].




End of Record #2177 - Last Modified: 05/30/97 11:56