Answers Database
OrCAD Capture: Design rule check gives "no matching pin" error for OFD16 component
Record #2177
Product Family: Software
Product Line: OrCAD
Product Part: capture
Problem Title:
OrCAD Capture: Design rule check gives "no matching pin" error for OFD16 component
Problem Description:
Priority: Urgency
Problem Description:
If you are using an OFD16 in an Orcad Capture design, you may get the following warning from the des
ign rule checker:
[DRC0012] Pin has no matching port in schematic below U...
and
[DRC0013]: Port has no matching pin in part instance above...
This warning message may be due to a problem with the library
symbol. Descend into the OFD16 component and check to see if
the output and input bus names have an index [15.0] instead of
[15..0] as they should be. (This was a problem in the original
Capture libraries.)
Orcad has been notified of this error.
Solution 1:
Call Orcad technical suppport for an updated library or descend into the OFD16 and change the bus in
dex to [15..0].
End of Record #2177 - Last Modified: 05/30/97 11:56 |