** OBSOLETE ** M1.5 LOGIBLOX: LogiBLOX will not save vendor information for vendor "Other"


Record #2241

Product Family: Software

Product Line: FPGA Implementation

Product Part: logiblox

Product Version: 1.3.

Problem Title:

** OBSOLETE ** M1.5 LOGIBLOX: LogiBLOX will not save vendor information for vendor "Other"


Problem Description:
Urgency: standard

General Description:
If you choose Vendor=Other in the LogiBLOX Setup menu,
LogiBLOX will notwrite the Vendor and Bus notation information
into the logiblox.ini file. This implies that you will need to
re-enter this information every time LogiBLOX (lbgui) is
invoked.


Solution 1:

As a workaround, you may choose the predefined Vendor setting
whose bus width delimiter matches that required by your
design entry tool. For example, if you need the bus delimiter
format to be set to "B", you should choose either Cadence
or Synopsys as the Vendor.

For your reference, this is the correspondence between
vendor and bus delimiter settings:


<LIST>
<LI>
  "B" is used by Cadence and Synopsys options
</LI>

<LI>
  "B(I)" is used by Mentor option
</LI>

<LI>
  "BI" is used by Viewlogic option
</LI>
</LIST>

This problem has been fixed in the 1.4 release.




End of Record #2241 - Last Modified: 03/02/99 17:50