Answers Database
** OBSOLETE ** M1.3 MAP gives misleading error: ERROR:0 - BLKNM parameter not supported on WAND symbol
Record #2319
Product Family: Software
Product Line: FPGA Implementation
Product Part: map
Product Version: 1.3.
Problem Title:
** OBSOLETE ** M1.3 MAP gives misleading error: ERROR:0 - BLKNM parameter not supported on
WAND symbol
Problem Description:
Urgency: standard
Reference: 12798
General Description:
If MAP gives the following error:
<OUTPUT>
ERROR:0 - BLKNM parameter not supported on WAND symbol
</OUTPUT>
The real problem here is that MAP does not support BLKNM for
WANDs which have a DECODE attribute attached. WANDs
which do not have a DECODE property can support BLKNM.
Solution 1:
Remove either the BLKNM or DECODE attribute from the WAND.
JG/KL
End of Record #2319 - Last Modified: 03/02/99 17:59 |