Answers Database
M1.3/M1.4 CPLD: Fitter does not recognize the vcc labelled net as a special net name
Record #2341
Product Family: Software
Product Line: FPGA Implementation
Product Part: ngdbuild
Product Version: 1.3.
Problem Title:
M1.3/M1.4 CPLD: Fitter does not recognize the vcc labelled net as a special net name
Problem Description:
Urgency: standard
General Description:
Xact-M1 no longer recognizes a sourceless net labelled vcc as
a special net name. This was allowed by the older versions,
but was not a design practice and is not a valid schematic
entry process.
Solution 1:
Solution:
Vcc nets should be connected to the "vcc" library element and
not left as sourceless nets labeled vcc.
End of Record #2341 - Last Modified: 10/04/97 13:54 |