PAR: WARNING:basdp - The SITE "pin-out" specified in the .PCF file was not found in desgin
Record #2504
Problem Title: In the error message, P32 is actually MD0(mode pin) for a PC84 package. This is not a standard I/O. The Boundary Scan and Mode pins: TDI, TCK, TMS, TDO, MD0, MD1, and MD2 are considered special purpose pins and will only be used if the TCK, TDI, TMS, TDO, MD0, MD1, and MD2 pads are specifically placed (instantiated) in the design. The others mentioned: HDC, LDC, INIT, DIN, DOUT do need to be prohibitted and will be used indescriminately by the software. M1 will issue an error message of the type "unknown site" if a prohibit is placed on a Boundary Scan or Mode pin site. Essentially, the user can be self assured that the M1 (Alliance) software will only use the Boundary Scan or Mode pins for I/O when the components are specifically placed (instantiated) in the design; there is no reason to prohibit those sites. PROGRAM, CCLK, and DONE cannot be prohibited since they are not I/Os. Solution 2: The P for P26 (or any other regular I/O) must be capitalized. End of Record #2504 - Last Modified: 12/12/97 16:02 |
| For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips! |