Answers Database
How to calculate sample rate for SDA filters.
Record #2625
Product Family: Software
Product Line: Coregen
Product Part: Coregen
Product Version: c1_4
Problem Title:
How to calculate sample rate for SDA filters.
Problem Description:
Keyword: Coregen, Sample, Rate, SDA, Filter
Urgency: Standard
How to calculate sample rate for SDA filters.
Solution 1:
The sample rate for SDA filters is determined by the system clock speed,
and the input data width.
For symmetrical filters:
Sample rate = system clock speed / (input data width + 1)
For non-symmetrical filters:
Sample rate = system clock speed / (input data width)
End of Record #2625 - Last Modified: 05/18/98 10:49 |