Answers Database


Workview Office: VSM Error 222. Could not find wir file XC9000 AND2B1.1


Record #2646

Product Family: Software

Product Line: ViewLogic

Product Part: vsm

Product Version: 5.2

Problem Title:
Workview Office: VSM Error 222. Could not find wir file XC9000 AND2B1.1


Problem Description:
Urgency: Standard

After successfully creating a schematic in Viewdraw, VSM (aka Create Digitial Netlist) reports the f ollowing:

ERROR 222. Could not find wir file XC9000 AND2B1.1

even thought the symbol appears in the library and on the schematic.


Solution 1:

Check the Viewlogic Project.

Ensure that all the libraries have the correct alias associated with them.

Example:

dir [p] c:\wvoffice\projects\my_proj (primary)
dir [r] c:\xact9000\unified\xc9000 (xc9000)
dir [r] c:\xact9000\unified\builtin (builtin)
dir [r] c:\xact9000\unified\xbuiltin (xbuiltin)




End of Record #2646 - Last Modified: 08/08/97 10:45