Answers Database
Workview Office: VSM Error 222. Could not find wir file XC9000 AND2B1.1
Record #2646
Product Family: Software
Product Line: ViewLogic
Product Part: vsm
Product Version: 5.2
Problem Title:
Workview Office: VSM Error 222. Could not find wir file XC9000 AND2B1.1
Problem Description:
Urgency: Standard
After successfully creating a schematic in Viewdraw, VSM (aka Create Digitial Netlist) reports the f
ollowing:
ERROR 222. Could not find wir file XC9000 AND2B1.1
even thought the symbol appears in the library and on the schematic.
Solution 1:
Check the Viewlogic Project.
Ensure that all the libraries have the correct alias associated with them.
Example:
dir [p] c:\wvoffice\projects\my_proj (primary)
dir [r] c:\xact9000\unified\xc9000 (xc9000)
dir [r] c:\xact9000\unified\builtin (builtin)
dir [r] c:\xact9000\unified\xbuiltin (xbuiltin)
End of Record #2646 - Last Modified: 08/08/97 10:45 |