Answers Database
Error: unable to open symbol template file. Logiblox: /sim/datareg0.1
Record #2692
Product Family: Software
Product Line: FPGA Implementation
Product Part: logiblox
Product Version: 1.5
Problem Title:
Error: unable to open symbol template file. Logiblox: /sim/datareg0.1
Problem Description:
Urgency: Standard
General Description:
The following error occurs when invoking the Logiblox GUI from Viewdraw:
Error: Unable to open symbol template file: logiblox/sym/counter0.1
for reading.
Error: logiblox:/sym/counter0.1 is corrupt or incomplete.
Solution 1:
This error can possibly occur if the logiblox sym directory was
corrupted.
Solution is to copy them back from the CD over to where logiblox
was installed.
Solution 2:
Add the logiblox and simprims library in viewdraw.ini file. The aliases (the
names in parenthesis) must match the library name. Also note that the logiblox
library is read-only, but not megafiled.
Example of viewdraw.ini file:
dir [p] C:\customer
dir [w] C:\customer (primary)
dir [rm] C:\Xilinx\viewlog\data\xc4000e (xc4000e)
dir [r] C:\Xilinx\viewlog\data\logiblox (logiblox)
dir [rm] C:\Xilinx\viewlog\data\simprims (simprims)
dir [rm] C:\Xilinx\viewlog\data\builtin (builtin)
dir [rm] C:\Xilinx\viewlog\data\xbuiltin (xbuiltin)
End of Record #2692 - Last Modified: 08/19/98 08:38 |