Answers Database


Error: unable to open symbol template file. Logiblox: /sim/datareg0.1


Record #2692

Product Family: Software

Product Line: FPGA Implementation

Product Part: logiblox

Product Version: 1.5

Problem Title:
Error: unable to open symbol template file. Logiblox: /sim/datareg0.1


Problem Description:
Urgency: Standard

General Description:
The following error occurs when invoking the Logiblox GUI from Viewdraw:

Error: Unable to open symbol template file: logiblox/sym/counter0.1
        for reading.
Error: logiblox:/sym/counter0.1 is corrupt or incomplete.


Solution 1:

This error can possibly occur if the logiblox sym directory was
corrupted.

Solution is to copy them back from the CD over to where logiblox
was installed.



Solution 2:

Add the logiblox and simprims library in viewdraw.ini file. The aliases (the
names in parenthesis) must match the library name. Also note that the logiblox library is read-only, but not megafiled.

Example of viewdraw.ini file:

dir [p] C:\customer
dir [w] C:\customer (primary)
dir [rm] C:\Xilinx\viewlog\data\xc4000e (xc4000e)
dir [r] C:\Xilinx\viewlog\data\logiblox (logiblox)
dir [rm] C:\Xilinx\viewlog\data\simprims (simprims)
dir [rm] C:\Xilinx\viewlog\data\builtin (builtin)
dir [rm] C:\Xilinx\viewlog\data\xbuiltin (xbuiltin)




End of Record #2692 - Last Modified: 08/19/98 08:38