Answers Database
Workview Office: How to install Sentinel driver for Windows NT 4.0 (error 8037)
Record #2699
Product Family: Software Device Status Startup -------- --------- --------- Sentinel Started Automatic If the Status does not show as Started, you can highlight Sentinel driver and click on Start. If you receive an error saying that the dependency service or group failed to start, you will need to follow the instructions listed below: 1) Close all applications and make sure nothing is running. 2) Delete the snti386.dll file in the c:\Winnt\system32 directory. 3) Re-start the computer. 4) Follow the directions in Resolution 1. Solution 2: Follow these steps to install the Sentinel driver for Windows NT 4.0: Note: In order to perform these steps you must have Administrative privileges. If you do not have this authority, contact your system administrator. 1. Select Start->Settings->Control Panel 2. Double-click on Multimedia 3. Select the Devices tab 4. Click the Add button 5. With "Unlisted or Updated driver" highlighted, click OK 6. With the Workview Office CD in the drive, browse to the Sentinel directory (i.e. D:\sentinel\) and click OK 7. Select "Sentinel for i386 systems" and click OK 8. All of the port settings will be automatically set. Click OK to accept the settings. 9. Restart Windows NT for this driver to take effect. End of Record #2699 - Last Modified: 03/03/98 13:07 |
| For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips! |