Answers Database
PAR: Error: rpc server is unavailable
Record #2891
Product Family: Software
Product Line: FPGA Implementation
Product Part: par
Product Version: 1.4.
Problem Title:
PAR: Error: rpc server is unavailable
Problem Description:
While running the flow engine gui, these error messages show up
after saying Par is done.
Error: rpc server is unavailable
Error: the object invoked has disconnected from it's clients.
Solution 1:
The problem is not well understood at this time, but appears to
be due to the design manager losing contact with a process that
it is running.
Workaround: If problem occurs frequently, an alternative is to run
the M1 tools from command line.
Solution 2:
Please make sure that you have free disk space available on your hard drive.
Lack of hard drive space is one reason this error has occured.
Solution 3:
One possible cause for this error is that the user's PC is configured to use a network card, but is
not able to. This could be caused by the network card being removed or installed incorrectly. To s
olve this, correctly install a network card into the system.
Solution 4:
Create a new project in design manager with same files. The old project may have gotten corrupted s
omehow.
End of Record #2891 - Last Modified: 11/12/99 14:34 |