Answers Database
Foundation F1.x Logic Simulator: ASCII test vector, cannot use u or p option for timing
Record #3138
Product Family: Software
Product Line: Aldec
Product Part: Foundation Logic Simulator
Product Version: 1.3
Problem Title:
Foundation F1.x Logic Simulator: ASCII test vector, cannot use u or p option for timing
Problem Description:
Urgency: Standard
General Description:
In ASCII format test vector file for Simulator (*.asc),
under #Timing block, if you put u (for microseconds) or
p (for picoseconds) to specify for the time, they will be ignored and read as nanoseconds in the wav
eform viewer.
Help file tells these options are available, but they
apparently are not.
Solution 1:
For microsecond, put extra 0's.
For picoseconds, put 0.00 in front.
End of Record #3138 - Last Modified: 03/03/99 11:37 |