Answers Database


XABEL, Foundation F1.x: Internal Error 18911 in Blif2net (abl2edif)


Record #3153

Product Family: Software

Product Line: Data I/O

Product Part: xabel

Product Version: 6.0

Problem Title:

XABEL, Foundation F1.x:	Internal Error 18911 in Blif2net (abl2edif) 


Problem Description:
Urgency: Standard

General Description:

The following error occurs during the blif2net program in
ABEL synthesis:

Internal Error 18911: Unable to find combinatorial gate
associated with <node_name>.

where <node_name> is a node with the "istype 'keep'" attribute.


Solution 1:

This is due to a bug in the Blif2net program, which is the
EDIF writer for XABEL. A possible workaround for CPLD
top-level Abel designs is to use the "Plusasm" flow, which will
write out a PLD instead of an EDIF file. Please see
(Xilinx Solution 2776) for more information on enabling this
flow.



Solution 2:

A workaround for this problem is to replace the
c:\xilinx\bin\nt\lib5\epld_dev.fft file with the one on the web
site at
ftp://ftp.xilinx.com/swhelp/foundation/xabelfix.zipInternet Link




End of Record #3153 - Last Modified: 03/03/99 11:39

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!