Answers Database
Hardware Debugger, M1.3 & M1.4 Lab Install, Error Baspm:Baspmdllm 174 & 187 dll open of library libx4xbs.dll
Record #3232
Product Family: Software
Product Line: M1 Graphical/General
Product Part: Hardware Debugger
Problem Title:
Hardware Debugger, M1.3 & M1.4 Lab Install, Error Baspm:Baspmdllm 174 & 187 dll open of
library libx4xbs.dll
Problem Description:
Urgency: Standard
General Description:
After installing the lab installation of Allaince or Foundation Implementation Tools, you load Hardw
are Debugger from the program menu. To download a .bit file, you create a new project by selecting
File -> New -> Project. You select your .bit or .mcs file and select Open.
The following error message appears in the Hardware Debugger Program in M1.3.7 Lab Install:
"FATAL_ERROR:baspm:baspmdllm.c:174:1.17-dll of library
<c:/Xilinx/xc4000ex/bin/nt/libx4xbs.dll> failed due to an unknown reason."
The following error message appears in Hardware Debugger of M1.4.12 Lab Install:
"FATAL_ERROR:baspm:baspmdllm.c:187:1.18-dll open of library
<c:/Xilinx/xc4000ex/bin/nt/libx4xbs.dll> failed due to an unknown reason."
Solution 1:
Copy the data directories from the Allaince CD or Foundation Implementation Tools CD into the lab in
stall xilinx directory. Copy the data directories that pertain to the design in question. The copy
ing can be done with Windows Explorer, and an example is as follows:
CDROM_Drive:\xc4000ex => Lab_Install_Drive:\xilinx\xc4000ex
CDROM_Drive:\xc4000xl => Lab_Install_Drive:\xilinx\xc4000xl
like D:\xc4000ex => c:\xilinx\xc4000ex
or any other data directory.
Copying is done by selecting the folder that you want to copy and then drag it to the destination an
d let go. You can also select the folder to copy, press the right mouse button and select copy. The
n select the destination folder and press the right mouse button and select paste.
Solution 2:
End of Record #3232 - Last Modified: 12/22/99 08:49 |