Answers Database
M1.5i/2.1i: NGDBUILD: OFFSET constraint gives "ERROR:basts:69 - NET CLK ... is not a pad-related net"
Record #3256
Product Family: Software
Product Line: Merged Core
Product Part: Timing
Problem Title:
M1.5i/2.1i: NGDBUILD: OFFSET constraint gives "ERROR:basts:69 - NET CLK ... is not a
pad-related net"
Problem Description:
Urgency: standard
General Description:
An offset constraint may give an error similiar to the following:
ERROR:basts:69 - NET "'CLK", which is the reference clock net for the NET OFFSET
"MYOUTPUT OUT : 5000.000000 pS : BEFORE : CLK" on NET "MYOUTPUT", is not a
pad-related net (i.e., it is not driven by a pad).
Solution 1:
The cause of this error is not having the OFFSET constraint applied to the net
between the pad and buffer. The clock net referenced must be the net between the
IPAD and BUFG or IBUF. The input or output net must be the net between the IPAD
and IBUF or OPAD and OBUF.
End of Record #3256 - Last Modified: 07/13/99 15:59 |