Answers Database


Foundation Logic Simulator: WARNING: More than one normal (Totem_Pole) output in the folloing node...


Record #3535

Product Family: Software

Product Line: Aldec

Product Part: Foundation Logic Simulator

Problem Title:
Foundation Logic Simulator: WARNING: More than one normal (Totem_Pole) output in the folloing node...



Problem Description:
Urgency: Standard

General Description:

When editing a Foundation Schematic, one may wish to replicate
portions of the schematic by copying and pasting. If a part of
the schematic (including both components and nets) is pasted so
that it is on the same level of hierarchy AND the Logic
Simulator window is open AND the net names of the copied
schematic have been user defined (i.e., "named"), then the
following warning may be generated by the simulator:

WARNING: More than one normal (Totem_Pole) output in the
folloing node: <net_name>, <net_name>, ...


Solution 1:

The above warning indicates that you have not changed the
net names for the copied schematic. The simulator is seeing
the two nets with the same name as one node.

The solution is to rename each of the user defined net names to
a distinct name. Then, from the Schematic Capture window goto
Options -> Update Simulation. This will reload the netlist in
the Simulator and will thus get rid of the warnings.




End of Record #3535 - Last Modified: 03/09/98 09:26

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!