Foundation Simulator, Logiblox, F1.4: Async_Val not simulated at power-up or GSR.


Record #3540

Product Family: Software

Product Line: Aldec

Product Part: Foundation Logic Simulator

Product Version: 1.4

Problem Title:
Foundation Simulator, Logiblox, F1.4: Async_Val not simulated at power-up or GSR.


Problem Description:
Urgency: Standard

General Description:
While simulating a Logiblox counter (functional or timing) with
Async_Val defined, the Async_Val value is not output at
power-up or upon assertion of the Global Set/Reset. Instead, the output of the counter is 0.


Solution 1:

Currently, the only way to simulate the power-up value of
Async_Val is to apply a logic 1 to the Async_Val pin of the
Logiblox counter.
Although the Async_Val value is not correctly displayed by the
simulator on power-up, it is correctly implemented in the
device. This can be verified in EPIC.




End of Record #3540 - Last Modified: 03/09/98 10:12