Answers Database


M1.5i: TRCE/Timing Analyzer: 0 items analyzed for OFFSET timespec


Record #3593

Product Family: Software

Product Line: FPGA Implementation

Product Part: Timing Analyzer

Product Version: 1.5

Problem Title:
M1.5i: TRCE/Timing Analyzer: 0 items analyzed for OFFSET timespec


Problem Description:
Urgency: Standard

General Description: TRCE will report that 0 Paths and 0 Items were
analyzed for an OFFSET timespec, if the flop is an IFF of OFF.


Solution 1:

Because all of the routing is fixed inside the IOB, Trace does not
report the paths inside the IOB including the flop. Therefore Trace
reports 0 items and 0 paths analyzed. The customer can find these
delays in the data book, they are spec'ed for full, partial and no delay.




End of Record #3593 - Last Modified: 08/02/99 09:36