Answers Database


A1.4 - Problems reading Answers Book from Dynatext viewer


Record #3741

Product Family: Software

Product Line: Other

Product Part: Dynatext

Problem Title:
A1.4 - Problems reading Answers Book from Dynatext viewer


Problem Description:
Urgency: Standard

General Description: Upon installing A1.4 and attempting to
view the Xilinx Answers book stating known issues with the
release, no books are seen and an error message may be seen
stating:

BwinList: FAILURE reading collection 'Answers'


Solution 1:

To be able to access the Answers books, they must have been
installed from the Xilinx Implementation Tools CD. On this CD
they are located in the userware/utilities directory.

The other problem is that the initialization file containing
the paths to the documentation is incorrect. To fix this, you
may edit the initialization file as follows:

For Win95/NT users
------------------

Open the $XILINX/bin/nt/dynatext.ini file in a text editor and edit the following lines:

Old:
COLLECTION=$XILINX\userware\utilities=Answers
COLLECTION=$XILINX_CD\userware\utilities=Answers on CD

New:
COLLECTION=$XILINX\userware\utilities\answers=Answers
COLLECTION=$XILINX_CD\userware\utilities\answers=Answers on CD


For UNIX users
--------------

Open the $EBTRC file which is usually located at, $XILINX/bin/<platform>/ebtrc, in a text editor and
  change the following lines:

Old:

COLLECTION	$XILINX/userware/utilities=Answers
COLLECTION	$XILINX_CD/userware/utilities=Answers on CD


New:

COLLECTION	$XILINX/userware/utilities/answers=Answers
COLLECTION	$XILINX_CD/userware/utilities/answers=Answers on CD





End of Record #3741 - Last Modified: 06/04/98 14:54