Answers Database
M1.4 PAR: FATAL_ERROR:basnd:basndutils.c:130:1.6 - Internal Error - signal has a loop
Record #3794
Product Family: Software
Product Line: FPGA Implementation
Product Part: par
Product Version: 1.4
Problem Title:
M1.4 PAR: FATAL_ERROR:basnd:basndutils.c:130:1.6 - Internal Error - signal has a loop
Problem Description:
Urgency: standard
General Description: When guiding the PAR without guiding the MAP and checking the box " match guid
e design exactly", the following error happens in PAR: FATAL_ERROR:basnd:basndutils.c:130:1.6 - Inte
rnal Error - signal has a loop, router problem? Process will terminate. Please call Xilinx support
.
Solution 1:
This is a bug in M1.4.12. It has been fixed in M1.5. Current workaround is to uncheck the box "match
guide design exactly".
End of Record #3794 - Last Modified: 05/21/98 08:57 |