Answers Database


WVO7.4, M1.4, 5200:ERROR: baste:266-An extension is required on the "RLOC" parameter for CY_MUX/FDCE


Record #3847

Product Family: Software

Product Line: ViewLogic

Product Part: Workview Office

Product Version: 7.5

Problem Title:
WVO7.4, M1.4, 5200:ERROR: baste:266-An extension is required on the "RLOC" parameter for CY_MUX/FDCE



Problem Description:
Urgency: Standard

General description:
Implementing a Viewlogic design, MAP may give the following error:

ERROR: baste:266-An extension is required on the "RLOC" parameter for FDCE
        symbol "<symbol name>" (output singnal=<netname>).

The same error may occur for CY_MUX symbols.

The error is generated because of an RLOC=R0C0 attribute on the FDCE within an
FJKC symbol.

This error will occur if a 'Flattened' netlist was generated from the Viewlogic EDIF Netlist writer instead of a 'Hierarchical' one.


Solution 1:

Make sure that the EDIF file is generated with the following options:

1. Netlist Options: Hierarchical (default)
2. LEVEL = XILINX or "Xilinx M1"




End of Record #3847 - Last Modified: 08/14/98 09:47

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!