Answers Database
Power sequencing issue forXC3100L, XC3000L, XC4000XL and Spartan-XL : where can we find the information
Record #3857
Product Family: Software
Product Line: M1 Implementation
Product Part: Spartan-XL Unified Libs
Problem Title:
Power sequencing issue forXC3100L, XC3000L, XC4000XL and Spartan-XL : where can we find
the information
Problem Description:
Urgency:
Standard
General Description
Sometimes customers would like to know if there is power sequencing problem with Xilinx low voltage
devices and do not know where they can find the information
Solution 1:
3.3 V and Mixed Voltage Compatible Products section of 1/98 Xilinx Databook (Page 6-1 to 6-4) contai
ns the required information. The information can also be found on the web at:
http://www.xilinx.com/partinfo/3volt.pdf
End of Record #3857 - Last Modified: 05/01/98 12:44 |