Answers Database


Foundation F1.4, XC95144-20: XC95144-20 device is available from Design Entry but not Implementation


Record #3897

Product Family: Software

Product Line: Aldec

Product Part: Foundation Project Manager

Product Version: 1.4

Problem Title:
Foundation F1.4, XC95144-20: XC95144-20 device is available from Design Entry but not Implementation



Problem Description:
Urgency: Standard

General Description:

In Foundation 1.4, the user is able to target a 95144-20 part, however in the Design Implementation tools, the -20 speed grade
is not supported.


Solution 1:

The XC95144-20 is not an available part and is not supported.

The bug lies in the Design Entry tools for showing this part
as available.




End of Record #3897 - Last Modified: 05/27/98 16:36