Answers Database
M1.4 Map - FATAL ERROR: Too many signals to move and not enough slots on comp
Record #3903
Product Family: Software
Product Line: FPGA Implementation
Product Part: map
Product Version: 1.4.
Problem Title:
M1.4 Map - FATAL ERROR: Too many signals to move and not enough slots on comp
Problem Description:
A map problem has been seen where a design fails with
the error:
FATAL_ERROR:x4kma:x4kmamerge.c:2858:1.145.12.11 - Too many
signals to move and not enough slots on comp
b3_u1_b4_b1_f1_0_b1_b2_b2_b4_u2_mid_carry_6_u1_no_rloc_u1 (76).
Process will terminate. Please call Xilinx support.
Solution 1:
This problem is fixed in the latest M1.4 Core Tools Update
available on the Xilinx Download Area:
Solaris: ftp://ftp.xilinx.com/pub/swhelp/M1.4_alliance/core_sol17_m14.tar.Z
SunOS ftp://ftp.xilinx.com/pub/swhelp/M1.4_alliance/core_sun17_m14.tar.Z
HPUX: ftp://ftp.xilinx.com/pub/swhelp/M1.4_alliance/core_hp17_m14.tar.Z
Win95/NT: ftp://ftp.xilinx.com/pub/swhelp/M1.4_alliance/core_nt17.zip
End of Record #3903 - Last Modified: 08/18/98 18:30 |