The readback bitstream in Dynatext is unclear.


Record #3957

Product Family: Software

Product Line: Other

Product Part: Dynatext

Product Version: 2.3

Problem Title:
The readback bitstream in Dynatext is unclear.


Problem Description:
Urgency: Standard

General Description:
   The readback bitstream for the 4k and 5200 are slightly different.
In Dynatext, it is unclear which bitream are being shown in the
figures and bitstream truely ends with 11 bits of a CRC value.


Solution 1:

The 4k readback bitstream ends with 11 CRC bits.

The 5200 readback bitstream end with the 16 CRC bits and then an 'FF1'.




End of Record #3957 - Last Modified: 08/25/98 07:41