Answers Database


M1.x: EPIC: How to add a probe to PROHIBITED iob


Record #4375

Product Family: Software

Product Line: FPGA Implementation

Product Part: Epic

Problem Title:
M1.x: EPIC: How to add a probe to PROHIBITED iob


Problem Description:
Urgency: Standard

General Description: Epic will not allow you add a probe to an iob site that has PROHIBIT constraint.

Prohibit pin information is constained in the pcf file. When EPIC is involked from Design Manager/Flow Engine gui the pcf file is loaded automatically. If EPIC was involked from the command line it will give you an option to load .pcf file.


Solution 1:

If you would like to invoke Epic from Design Manager/Gui or would like to use Epic with .pcf constraints, yet, would like to be able to use IOB that has been previously prohibited, use the following workaround:

1)Close the Epic window if it is currently open.

2)Edit the .pcf file and comment out the PROHIBIT contraint line for the IOB which you would like to use.

3)Re-open Epic again, and now the PROHIBIT constraint is gone, and should be able to add a probe to this IOB.

For more information on How to add a probe or route out a signal in Epic, see Xilinx Answer record #2979 at:

http://www.xilinx.com/techdocs/2979.htm




End of Record #4375 - Last Modified: 05/26/99 07:41