Answers Database
F1.5: Virtex Configuration Stage - Project Manager reports Implementation Errors
Record #4391
Product Family: Software
Product Line: Aldec
Product Part: Foundation Project Manager
Problem Title:
F1.5: Virtex Configuration Stage - Project Manager reports Implementation Errors
Problem Description:
Urgency: Hot
When running through the Virtex design flow, the Flow Engine completes all
stages except Configuration without fault. The Project Manager reports that
Configure fails with errors:
Xie: Flow Engine: ver2->rev1 (Timed ERRORS)
Xie: Flow Engine: ver2->rev1 (ERRORS Implemented)
The Bitgen report simply reports a warning:
WARNING:basbs:134 - bitgen only supports DRC on this device.
No ERRORS are reported anywhere.
Solution 1:
Bitstream generation for Virtex devices will be enabled with the F1.5
Performance Pack. Until that release is available, please deselect the
"Produce Configuration Data" checkbox in the Implementation Options.
End of Record #4391 - Last Modified: 09/21/98 15:00 |