Answers Database
Foundation F1.5: Cannot show 'Create Version' dialog -- automation caused exception, exit code 80010105
Record #4653
Product Family: Software
Product Line: Aldec
Product Part: Foundation Project Manager
Problem Title:
Foundation F1.5: Cannot show 'Create Version' dialog -- automation caused exception, exit
code 80010105
Problem Description:
Date: 9/98
Urgency: Hot
General Description:
After opening the global synthesis options dialog (Synthesis -> Options) from
the F1.5 Project Manager, you many encounter the following error when
attempting to synthesize or implement the design:
Pcm: Cannot show 'Create Version' dialog -- Automation caused an exception,
exit code 80010105.
The error may also be accompanied by "XIE" errors. The Project Manager will become locked up at thi
s time, and the machine may need to be rebooted to fully
recover. In some cases, Windows will become locked up.
This has only been seen with Windows 95.
Solution 1:
A patch has been developed that corrects this problem. The file can be
downloaded from the Xilinx FTP site:
ftp://ftp.xilinx.com/pub/swhelp/foundation/f15pcmv1.zip
Solution 2:
Rebooting the machine should also fix the problem. However, the same problem
will occur the next time the global synthesis options dialog is opened. Since
this dialog is usually opened only once for each project, this may be an
acceptable workaround if access to the patch described in Resolution #1 is not
available.
End of Record #4653 - Last Modified: 09/22/98 16:26 |