Answers Database


M1.5: Constrainst Editor: Net pulldown window in Timing Ignore Dialog does not show long net names


Record #4741

Product Family: Software

Product Line: M1 Implementation

Product Part: Constraints Editor

Product Version: 1.5

Problem Title:
M1.5: Constrainst Editor: Net pulldown window in Timing Ignore Dialog does not show long net names



Problem Description:
Urgency: Standard

does not allow any way to see the full name. There is no left/right scroll or highlight box to show long names.


Solution 1:

This is only a visual problem. If you create a tig using the net, the entire net name is written to the ucf file correctly.

The visual issue will be resolved in the 1.5 Performance Pack.




End of Record #4741 - Last Modified: 05/26/99 14:00

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!