Answers Database
A1.5 Service Pack CD Install for Workstation. The CD is dated September 98.
Record #4853
Product Family: Software
Product Line: M1 Graphical/General
Product Part: Install
Product Version: 1.5
Problem Title:
A1.5 Service Pack CD Install for Workstation. The CD is dated September 98.
Problem Description:
Urgency: Standard
to the size of the update Xilinx has made available a CD version of this update. This
solution clarifies any installation issues for the workstation.
Also explains how to create a MYXILINX area.
Solution 1:
Issues to be aware of:
1- The installer must be run in a writable directory. Run the install program on the
cdrom specifying the full path: (For Example: /cdrom/srvcpk/install)
2- The installer does not support the MYXILINX directory and variable. The installation
destination must be a current installation of M1.5_19.
3- The destination path must be specified from the root directory (/home).
Solution 2:
The installer does not support the use of a MYXILINX area. This will explain how to
create this area.
1- Create the MYXILINX directory in /home/user_name/MYXILINX.
2- cd to the root of the cdrom.
3- cd to the srvcpk/sol or srvcpk/hp directory depending on the operating system.
4- Run the following command: cp -rp * /home/user_name/MYXILINX
Note: Creating a MYXILINX area can result in possible problems for devices that are
not installed in the XILINX area. This is because a subset of the required data files for
a specific family are installed to the MYXILINX area and not the XILINX area. This
results in families and parts showing up in the Design Manager and EPIC as valid
families/parts. Using these families/parts can result in errors in the software. To avoid these prob
lems do not run the software on families/parts not
installed to the XILINX area.
End of Record #4853 - Last Modified: 10/20/98 12:44 |