Answers Database


A1.5 Service Pack CD Install for Workstation. The CD is dated September 98.


Record #4853

Product Family: Software

Product Line: M1 Graphical/General

Product Part: Install

Product Version: 1.5

Problem Title:
A1.5 Service Pack CD Install for Workstation. The CD is dated September 98.


Problem Description:
Urgency: Standard

to the size of the update Xilinx has made available a CD version of this update. This solution clarifies any installation issues for the workstation.

Also explains how to create a MYXILINX area.


Solution 1:

Issues to be aware of:

1- The installer must be run in a writable directory. Run the install program on the
      cdrom specifying the full path: (For Example: /cdrom/srvcpk/install)

2- The installer does not support the MYXILINX directory and variable. The installation
      destination must be a current installation of M1.5_19.

3- The destination path must be specified from the root directory (/home).




Solution 2:

The installer does not support the use of a MYXILINX area. This will explain how to create this area.

1- Create the MYXILINX directory in /home/user_name/MYXILINX.
2- cd to the root of the cdrom.
3- cd to the srvcpk/sol or srvcpk/hp directory depending on the operating system.
4- Run the following command: cp -rp * /home/user_name/MYXILINX

Note: Creating a MYXILINX area can result in possible problems for devices that are not installed in the XILINX area. This is because a subset of the required data files for a specific family are installed to the MYXILINX area and not the XILINX area. This results in families and parts showing up in the Design Manager and EPIC as valid families/parts. Using these families/parts can result in errors in the software. To avoid these prob lems do not run the software on families/parts not
installed to the XILINX area.




End of Record #4853 - Last Modified: 10/20/98 12:44