Answers Database


Foundation F1.5 State Editor: Incorrect ABEL code generation when you have two state machines (L109/C15)


Record #5019

Product Family: Software

Product Line: Aldec

Product Part: Foundation State Editor

Product Version: 1.5

Problem Title:
Foundation F1.5 State Editor: Incorrect ABEL code generation when you have two state machines (L109/C15)



Problem Description:
KEY WORDS : fsm, foundation, abel, state machines, state editor, L109/C15

URGENCY : Standard

General Description :
When generating abel code for 2 state machines from the State Editor, the clk definition of the seco nd state machine is placed incorrectly resulting in the
following error during synthesis.

Error L109/C15 : Syntax Error 1028: EQUATIONS, STATE_DIAGRAM, TRUTH_TABLE or END expected.


Solution 1:


Place " Equation" command before the second state machine's clock definition.




Solution 2:

Move the second state machine's clock definition so that it be excuted just after the first state ma chine's clock definition.




End of Record #5019 - Last Modified: 11/23/98 13:51