Answers Database


Foundation F1.5: Lmacs:58 The compression buffer length is too short, btrieve


Record #5110

Product Family: Software

Product Line: Aldec

Product Part: Foundation Project Manager

Product Version: 1.5

Problem Title:
Foundation F1.5: Lmacs:58 The compression buffer length is too short, btrieve


Problem Description:
urgency: Standard

General Description:

An 'Lmacs:58' error may occur when working with library symbols in
Foundation. This error can happen when the Btrieve parameter called
'Largest Compressed Record Size' is too small.


Solution 1:

The BTI Database Setup Utility can be used to modify the value of this
parameter.   This utility is located in the in the $XILINX\active\butils
directory.

1. Start up the utility by going to the %XILINX%\Active\Butils
      directory via the Windows Explorer and doubling clicking on
      W32MKSET.EXE.
2. Select 'Memory Resources' in the upper left hand window.
3. Select 'Largest Compressed Record Size' in the lower left hand window.
4. Change the 'Current:' number to one that is greater than the current
       number, for example 256 or 512.
5. Click on the 'Save' button and then exit the program.
6. Restart the computer.




End of Record #5110 - Last Modified: 12/11/98 13:32