Answers Database


F1.5i/2.1i: Taengine produces Timing report with no data - too many paths to trace


Record #5111

Product Family: Software

Product Line: CPLD Implementation

Product Part: taengine

Product Version: 1.5i

Problem Title:
F1.5i/2.1i: Taengine produces Timing report with no data - too many paths to trace


Problem Description:

Urgency:    Hot

General Description:
The report is displayed under Implementation Log files, but when opening the file, it just contains the Header of the file. Under Logical Path, there is no information.


Solution 1:

There are too many paths for Taengine to cover. You can try running command line:

taengine -f <design> -plimit 1000000

This command line will limit the number of paths and generate a report.






End of Record #5111 - Last Modified: 06/29/99 15:38

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!