Answers Database


LogiCORE PCI32 4000: The timespec "USER_PADS" in the UCF files is incorrect for Viewlogic Flow


Record #5275

Product Family: Documentation

Product Line: PCI Apps

Product Part: PCI Design Solutions

Problem Title:
LogiCORE PCI32 4000: The timespec "USER_PADS" in the UCF files is incorrect for Viewlogic Flow



Problem Description:
Urgency: Standard

General Description:

The timespec "USER_PADS" in the UCF files is incorrect for the
Viewlogic PowerView and WorkView Office flows.


Solution 1:

Exclude the "GNT_PAD" from the "USER_PAD" timegroup. The correct
statement is

USER_PADS = PADS except PCI_PADS : GNT_PADS ;




End of Record #5275 - Last Modified: 10/01/99 14:39