Answers Database
F1.5/F1.5i Project Manager: Checking Implementation reports gives "Template Engine" error box.
Record #5281
Product Family: Software
Product Line: Aldec
Product Part: Foundation Project Manager
Product Version: 1.5
Problem Title:
F1.5/F1.5i Project Manager: Checking Implementation reports gives "Template Engine" error
box.
Problem Description:
Urgency : Standard
General Description:
The user is not able to look at the implementation
reports generated from F1.5.
1) From the Foundation Project Manager (PCM) the user
selects the "Reports" tab.
2) Then the user double clicks on "Implementation
Reports File"
3) The Xilinx Report Browser window comes up with the
available reports but, if the user double clicks
on any of the reports for viewing, a windows
error box pops up.
The box says, "Template Engine" at the top. The
body of the window contains a yellow triangle with
an exclamation point and an "OK" button. There are
no message about the error.
The Implementation Log File and other log files in
PCM report section open correctly.
Solution 1:
This error can be caused by having an unknown editor
as the default editor in Design Manager.
Open Design Manager by selecting START -> Programs ->
<Xilinx Foundation Series> -> Accessories -> Design
Manager.
Select File -> Preferences
Browse to find a preferred editor to place in the
"Editor for viewing files:" dialog box.
NOTE: There is also Text Editor selection available in
PCM under File -> Preferences -> Configuration.
This selection has no effect on the "Template
Engine" error.
End of Record #5281 - Last Modified: 03/01/99 14:47 |