Answers Database


LogiCORE PCI: What loads should be used when calculating maximum clock-to-out timing?


Record #5299

Product Family: Documentation

Product Line: PCI Apps

Product Part: PCI Frequently Asked Questions

Problem Title:
LogiCORE PCI: What loads should be used when calculating maximum clock-to-out timing?


Problem Description:
Urgency: Standard

General Description:

What loads should be used when calculating maximum
clock-to-out timing?


Solution 1:

The 5.0v PCI spec calls for the output buffer to be loaded
with 50pF when measuring clock-to-out timing.

The 3.3v PCI spec (including the 66MHz spec) calls for the
output buffer to be loaded with 10pF with a 25 ohm resistor
in parallel




End of Record #5299 - Last Modified: 02/23/99 12:54