M1.5: Floorplanner: RPMs are incorrectly displayed in the Floorplanner
Record #5365
Product Family: Software
Product Line: Merged Core
Product Part: Floorplanner
Product Version: 1.5
Problem Title:
M1.5: Floorplanner: RPMs are incorrectly displayed in the Floorplanner
Problem Description:
Urgency: Standard
General Description: Relationally Placed Macros or RPMs contain specific
placement information. The Floorplanner improperly translates this information
for specific designs resulting in a Floorplan DRC ERROR.
Solution 1:
Follow these steps to resolve the ERROR:
1- Run the design through PAR or Place and Route.
2- Load the Placed and Routed NCD file with the NGD file into Floorplanner.
3- Run the Check Floorplan to find the RPM which is improperly translated.
4- Select the RPM in the Floorplan Window.
5- Hit the "Delete" key.
6- Select "Constrain from Placement" from the Floorplan menu.
This will properly build the RPM and place it in the Floorplan window. The
user can now Floorplan the RPM.
End of Record #5365 - Last Modified: 05/24/99 13:34 |