Answers Database


1.5i Virtex Map - FATAL_ERROR:xvkma:xvkmap.c:587:1.112. Cannot find IOB attached to IBUFG


Record #5424

Product Family: Software

Product Line: FPGA Implementation

Product Part: map

Product Version: 1.5i

Problem Title:

1.5i Virtex Map - FATAL_ERROR:xvkma:xvkmap.c:587:1.112. Cannot find IOB attached to IBUFG


Problem Description:
Urgency: Standard

General Description: Virtex design implemented in M1.5i results
in the following error:
FATAL_ERROR:xvkma:xvkmap.c:586:1.112. Cannot find IOB attached
to IBUFG.


Solution 1:

This particular case was due to a illegal clock circuit configuration. The 2.1i version of map fails with a user error on this design:

ERROR:xvkpu - The symbol $I598 failed to join a global clock I/O component
as required. Clock I/O component can accept input pads only. Problem encountered during the packing phase.




End of Record #5424 - Last Modified: 04/13/99 19:01