Answers Database


F1.5/F1.5i Project Manager: Automation failed, exit with error code 80080005


Record #5472

Product Family: Software

Product Line: Aldec

Product Part: Foundation Project Manager

Product Version: 1.5

Problem Title:
F1.5/F1.5i Project Manager: Automation failed, exit with error code 80080005


Problem Description:
Urgency: Standard

General Description:

When the Project Manager starts, or when other options are selected
(such as accessing a menu option) the following appears:
Automation failed, exit with error code 80080005.


Solution 1:

This can be the result of a bad registery setting for xie32.exe
or the executable itself missing from fndtn\bint\nt. Before
modifying the registry, copy xie32.exe to the correct directory.

Verifying the registry setting using the following steps:

1- Goto "Start -> Run", type regedit and select "Ok".
2- In the Registry Editor select "Edit -> Find".
3- In the Find dialog enter xie32.
4- The path displayed must point to the currently installed xie32.exe.
     This executable is located in the fndtn\bin\nt directory.
5- If the path is incorrect, select "Default" and right click with the
     mouse. This will open the Edit String dialog allowing you to
     modify the path.
6- Save the registry and exit.
7- Restart Foundation.




Solution 2:

This can result from the absence of Windows NT Service Pack 3.
WinNT Service Pack 3 is required to run Foundation F1.5/F1.5i.
Service Pack 3 may be downloaded from Microsoft at
http://www.microsoft.comInternet Link




End of Record #5472 - Last Modified: 04/06/99 13:24