1.5i PAR - Leveage guided PAR fails with NTERNAL_ERROR:basnd:basndtiming.c:647:1.25.1.2 -...
Record #5532
Problem Title:
1.5i PAR - Leveage guided PAR fails with NTERNAL_ERROR:basnd:basndtiming.c:647:1.25.1.2 -...
Problem Description:
INTERNAL_ERROR:basnd:basndtiming.c:647:1.25.1.2 - We should have a node here.
On an unchanged design, leveage guided PAR fails w/INTERNAL_ERROR.
Work around is to use Exact mode.
Solution 1:
A fix for this problem is included in the 1.5i Service Pack 1. For details
on this Service Pack see http://www.xilinx.com/techdocs/5514.htm
End of Record #5532 - Last Modified: 02/19/99 18:21 |