Answers Database
1.5i PAR - A design fails in PAR with ERROR:xvkap:62 - IOB IOBUFAGP is incompatible with SelectIO standards ...
Record #5546
Product Family: Software
Product Line: FPGA Implementation
Product Part: par
Product Version: 1.5i
Problem Title:
1.5i PAR - A design fails in PAR with ERROR:xvkap:62 - IOB IOBUFAGP is incompatible with
SelectIO standards ...
Problem Description:
Error in PAR, ERROR:xvkap:62 - IOB IOBUFAGP is incompatible with SelectIO standards have already be
en locked into the same IO bank. Examine Bank[7] in the Summary report.
This problem occurrs when trying to lock an IOB that requires a VREF into a VREF site. This is an i
llegal configuration. When the DRC fails, the SelectIO summary report should be printed to describ
e the user error. '
Solution 1:
A fix for this problem is included in the 1.5i Service Pack 1. For details
on this Service Pack see http://www.xilinx.com/techdocs/5514.htm
End of Record #5546 - Last Modified: 02/20/99 19:39 |