Answers Database


1.5i PAR - A design fails in PAR with ERROR:xvkap:62 - IOB IOBUFAGP is incompatible with SelectIO standards ...


Record #5546

Product Family: Software

Product Line: FPGA Implementation

Product Part: par

Product Version: 1.5i

Problem Title:

1.5i PAR - A design fails in PAR with ERROR:xvkap:62 - IOB IOBUFAGP is incompatible with SelectIO standards ...



Problem Description:
Error in PAR, ERROR:xvkap:62 - IOB IOBUFAGP is incompatible with SelectIO standards have already be en locked into the same IO bank. Examine Bank[7] in the Summary report.

This problem occurrs when trying to lock an IOB that requires a VREF into a VREF site. This is an i llegal configuration. When the DRC fails, the SelectIO summary report should be printed to describ e the user error. '


Solution 1:

A fix for this problem is included in the 1.5i Service Pack 1. For details
on this Service Pack see http://www.xilinx.com/techdocs/5514.htmInternet Link




End of Record #5546 - Last Modified: 02/20/99 19:39