Answers Database


1.5i SP2 XC4000XV PAR - Most of the paths on octal lines in 4000xv are not being represented as being buffered.


Record #5556

Problem Title:

1.5i SP2 XC4000XV PAR - Most of the paths on octal lines in 4000xv are not being represented as being buffered.



Problem Description:
Most of the paths on octal lines in 4000xv are not being represented as being buffered. As a result, timing for 4000xv designs is not good.


Solution 1:

A fix for this problem is included in 1.5i Service Pack 2. For more information see:

   (Xilinx Solution #5887)




End of Record #5556 - Last Modified: 03/29/99 09:45

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!