Answers Database
Exemplar: After upgrading from Spectrum 1998.2d build 5.94 to 1998.2d build 5.103 my project now targets Spartan where the saved project was targeting Virtex?
Record #5681
Product Family: Software
Product Line: Exemplar
Product Part: Leonardo Spectrum
Product Version: 1998.2
Problem Title:
Exemplar: After upgrading from Spectrum 1998.2d build 5.94 to 1998.2d build 5.103 my project
now targets Spartan where the saved project was targeting Virtex?
Problem Description:
Urgency: Standard
General Description:
After downloading the Exemplar Leonardo Spectrum update from 19982d Build 5.94, to
1998.2d Build 5.103, my project that I opened from a saved project is now targeting
Spartan, where as when I initially saved the project was targeting Virtex.
Solution 1:
Exemplar incoporated some code changes the ended up changing a saved project that was
targeting Virtex, to Spartan, when opened.
The easy and only way around this is to open the saved project re-enter in the part
that you wish to target, and re-save the project.
End of Record #5681 - Last Modified: 02/16/99 17:07 |