Answers Database


V1.5, V1.4 COREGEN: Coregen EDIF targets 4013EPQ240-3 part when architecture is set to 4000 and Spartan families


Record #5756

Product Family: Software

Product Line: Coregen

Product Part: Coregen

Problem Title:
V1.5, V1.4 COREGEN: Coregen EDIF targets 4013EPQ240-3 part when architecture is set to 4000 and Spartan families



Problem Description:
Urgency: standard

General Description:
The EDIF Implementation Netlist generated by Coregen specifies
a target part type of 4013EPQ240-3when the target architecture
is set to XC4000 and Spartan families.


Solution 1:

The choice of the 4013EPQ240-3as the target part type within the EDIF file generated by Coregen is arbitrary. During the subsequent implementation of the design,
this part type is overridden by the one passed to NGDBUILD in the Xilinx Design Manager or Foundation Project Manager. In addition, Coregen does not currently
build modules differently when targeting Spartan and XC4000 devices, so the
embedded part type of 4013 should not be of concern.




End of Record #5756 - Last Modified: 03/02/99 20:03

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!