Answers Database
1.5i SP2 Hitop - Hitop fails to select 9536XL and 9572XL devices in autoselect mode.
Record #5834
Product Family: Software
Product Line: CPLD Implementation
Product Part: hitop
Product Version: 1.5i
Problem Title:
1.5i SP2 Hitop - Hitop fails to select 9536XL and 9572XL devices in autoselect mode.
Problem Description:
Hitop uses a 95144XL device when autoselect is used. But is
successful if directed to use 9536XL device.
Solution 1:
A fix for this problem is available in the 1.5i Service Pack2:
(Xilinx Solution #5887)
End of Record #5834 - Last Modified: 03/29/99 09:42 |