M1.5i Virtex Pin2ucf - An incorrect signal name is used in the .ucf data for Clock signals in Virtex devices.


Record #5927

Product Family: Software

Product Line: FPGA Implementation

Product Part: pin2ucf

Problem Title:
M1.5i Virtex Pin2ucf - An incorrect signal name is used in the .ucf data for Clock signals in Virtex devices.



Problem Description:
Urgency: Standard

General Description:

An incorrect signal name is used in the .ucf data for Clock signals in Virtex devices. In the case seen, the signal clk was replaced by clk.PAD/PAD_SIG.


Solution 1:

This problem can be worked around by manually changing the UCF data
  to the correct signal name.

This problem is scheduled to be fixed in the 2.1i release scheduled to begin
shipping in June, 1999.




End of Record #5927 - Last Modified: 05/24/99 09:31