Answers Database
M1.5i Virtex Pin2ucf - An incorrect signal name is used in the .ucf data for Clock signals in Virtex devices.
Record #5927
Product Family: Software
Product Line: FPGA Implementation
Product Part: pin2ucf
Problem Title:
M1.5i Virtex Pin2ucf - An incorrect signal name is used in the .ucf data for Clock signals
in Virtex devices.
Problem Description:
Urgency: Standard
General Description:
An incorrect signal name is used in the .ucf data for Clock signals in Virtex devices.
In the case seen, the signal clk was replaced by clk.PAD/PAD_SIG.
Solution 1:
This problem can be worked around by manually changing the UCF data
to the correct signal name.
This problem is scheduled to be fixed in the 2.1i release scheduled to begin
shipping in June, 1999.
End of Record #5927 - Last Modified: 05/24/99 09:31 |