Answers Database


Hitop: Impelemented Equations within the Fitter Report don't have the .pin or .fb extensions when using ABEL.


Record #6090

Product Family: Software

Product Line: CPLD Implementation

Product Part: Abel

Problem Title:
Hitop: Impelemented Equations within the Fitter Report don't have the .pin or .fb extensions when using ABEL.



Problem Description:

Urgency:    Standard

General Description: The fitter report did not show the .pin extension, but
this did show up in the timing simulation.


Solution 1:

This has been fixed for the next release 2.1i.

The implemented equations are incorrect in the fitter report for ABEL
9500 designs. Designs were verified to have implemented correctly
and the signal should appear correctly in the timing simulation. The
correction will be made to the fitter report in the next release of the
software.






End of Record #6090 - Last Modified: 05/19/99 15:53

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!