Answers Database


MAP v1.5is2, COREGEN, SDA FIR: x4kma : 339 - The (symname) symbol "xx/xx" has no signal connected to B1. This pin must be connected . . .


Record #6134

Product Family: Software

Product Line: Coregen

Product Part: Coregen

Problem Title:

MAP v1.5is2, COREGEN, SDA FIR:	x4kma : 339 - The (symname) symbol "xx/xx" has no signal
connected to B1. This pin must be connected . . .



Problem Description:
Urgency : Standard

General Description:

   This error may occur when using a PDA FIR.
   This is the error message returned by MAP:

ERROR:x4kma:339 - The HIERCY4_03 symbol "U7/B176" (output signal=U7/N5940) has
    no signal connected to B1. This pin must be connected based on carry moded
    ADD-G-F1


Solution 1:


This error message may appear because the SDA FIR Filter module had
the 'Cascade' option selected when it was generated, but the module was
not being cascaded with another SDA FIR module in the design.

Ensure that you make the proper connections when cascading two or
more SDA FIR filters when generating an SDA FIR with a Cascadeable
Section (see the datasheet for the filter). If you are not going to cascade
two or more SDA FIR filters together, do not activate the "Generate
Cascadeable Section" checkbox.




End of Record #6134 - Last Modified: 06/10/99 15:47

For the latest news, design tips, and patch information on the Xilinx design environment, check out the Technical Tips!