M1.5i/2.1i: Timing Analyzer: There is a limit to the number of paths reported per timing constraint, 4096.
Record #6226
Product Family: Software
Product Line: FPGA Implementation
Product Part: Timing Analyzer
Product Version: 1.5is2
Problem Title:
M1.5i/2.1i: Timing Analyzer: There is a limit to the number of paths reported per timing
constraint, 4096.
Problem Description:
Urgency: Standard
General Description:
In running trace, the timing analyzer, the user generates a report
containing an unlimited number of paths reported per timing constraint.
There is a hard limit to how many are actually reported, which is 4096 paths.
Solution 1:
The path report limit is 4096. The user will have to customize his reports
to specific paths.